Voice floor Annunciation System for Elevator
- Size: 120 * 70 mm (Millimeter) or 12*7 cm (Centimeter),
- Thickness: 25 mm or 2.5 cm
Features:
- Operating Voltage: 12V/24V
- Up to 16 wire connection for multipurpose based on customer requirements
- Floor Announcement: Ground Floor till 19th Floor, Basement -1, 2, 3. Parking-1, 2, 3. Terrace-1, 2, 3.
- Lift is undermaintenace – UM connection in PCB layout
- Lift is Overloaded – OL connection in PCB layout
- Lift having Fire Alarm- FI connection in PCB layout,
- You are Welcome – P connection in PCB layout
- Please close the door – O connection for Manual Door lift in PCB layout
- Emergency Rescue Device is activated, please don’t Panic- R connection for ARD in PCB layout.
- Lift is going Down- D connection in PCB layout.
- Lift is going Up – U connection in PCB layout.
- Floor, Parking, Terrace, Basement announcement- Use connection between A and 2 in PCB layout
- Separate Power & Speaker Connections. For LED Indication use connect wire between Power Positive (+) and + connection for the same in PCB layout.
Wiring Connection Details:
|
SYMBOL |
SPECIFICATION |
|
+ |
Loop Cable with Power Positive Connection |
|
A |
Seven Segment Connection input from Control Panel |
|
B |
Seven Segment Connection input from Control Panel |
|
C |
Seven Segment Connection input from Control Panel |
|
D |
Seven Segment Connection input from Control Panel |
|
E |
Seven Segment Connection input from Control Panel |
|
F |
Seven Segment Connection input from Control Panel |
|
G |
Seven Segment Connection input from Control Panel |
|
2 |
10 Plus Seven Segment Connection input from Control Panel |
|
UP |
UP Connection input from Control Panel |
|
DN |
Down Connection input from Control Panel |
|
AR |
ARD connection input from Control Panel |
|
O |
Manually Close Door Connection input from Control Panel |
|
P |
Welcome Connection input from Control Panel |
|
OL |
Overload Connection input from Control Panel |
|
UM |
Under Maintenance Connection input from Control Panel |
|
FI |
Fire Connection coming from Control Panel |
|
+ |
Power Cable (12V/24V)-Positive |
|
- |
Power Cable(12V/24V)-Negative |
|
SPEAKER |
|
|
+ |
Positive Cable |
|
- |
Negative Cable |
Voice floor Annunciation System for Elevator (Compact Size)
- Size: 120 * 40 mm (Millimeter) or 12*4 cm (Centimeter),
- Thickness: 15 mm or 1.5 cm
Features:
- Operating Voltage: 12V/24V
- Up to 14 wire connection for multipurpose based on customer requirements
- Floor Announcement: Ground Floor till 19th Floor, Basement -1, 2, 3. Parking-1, 2, 3. Terrace-1, 2, 3.
- Lift is undermaintenace
- Lift is Overloaded – OL connection in PCB layout
- You are Welcome – W connection in PCB layout
- Please close the door – LB connection for Manual Door lift in PCB layout
- Emergency Rescue Device is activated, please don’t Panic- R connection for ARD in PCB layout.
- Lift is coming Down- D connection in PCB layout.
- Lift is going Up – U connection in PCB layout.
- Floor, Parking, Terrace, Basement announcement- Use connection between A and 2 in PCB layout
Wiring Connection Details:
|
SYMBOL |
SPECIFICATION |
|
A |
Seven Segment Connection input from Control Panel |
|
B |
Seven Segment Connection input from Control Panel |
|
C |
Seven Segment Connection input from Control Panel |
|
D |
Seven Segment Connection input from Control Panel |
|
E |
Seven Segment Connection input from Control Panel |
|
F |
Seven Segment Connection input from Control Panel |
|
G |
Seven Segment Connection input from Control Panel |
|
2 |
10 Plus Seven Segment Connection input from Control Panel |
|
U |
UP Connection input from Control Panel |
|
D |
Down Connection input from Control Panel |
|
R |
ARD connection input from Control Panel |
|
LB |
Manually Close Door Connection input from Control Panel |
|
OL |
Overload Connection input from Control Panel |
|
W |
YOU ARE WELCOME Connection input from Control Panel |
|
+ |
Power Cable (12V/24V)-Positive |
|
- |
Power Cable(12V/24V)-Negative |
|
SPEAKER |
|
|
+ |
Positive Cable |
|
- |
Negative Cable |